dc.description | Ushkarenko, O. O. Improvement of monitoring means of voltage unbalance factor in shipboard electrical power system / O. O. Ushkarenko, O.Y. Domanskyi // Матеріали I Міжнар. наук.-практ. конф. "Проблеми сталого розвитку морської галузі" (PSDMI-2021). – Херсон : ХДМА, 2021. – С. 176–180. – Режим доступу : https://ksma.ks.ua/wp-content/uploads/2021/11/PSDMI-2021.pdf | uk_UA |
dc.description.abstract | Суднові електроенергетичні системи (СЕЕС) є ізольованими та автономними. У трифазній системі може виникнути несиметрія напруги через ненульовий опір джерела живлення і різниці фазних навантажень. Якість електроенергії за коефіцієнтом дисбалансу вважається такою, що відповідає нормам, якщо загальна тривалість її виходу за нормально допустимі значення (2%) становить не більше 1 години 12 хвилин на добу. Крім того, не повинно бути вимірів, що перевищують максимально допустиме значення (4%). В електричних машинах (наприклад, асинхронних двигунах) через появу додаткових магнітних полів, що обертаються в напрямку, протилежному напрямку обертання ротора, термін їх служби скорочується на 10-15%. Знижується ККД силових (синхронних) генераторів. Також несиметрія напруги призводить до збільшення втрат в нульовому проводі при передачі електроенергії. У цьому випадку можливе порушення безперебійного електропостачання, вихід з ладу комп’ютерів та іншого обладнання. Тому актуальним є удосконалення систем вимірювання та контролю якості електроенергії в трифазних мережах. | uk_UA |
dc.description.abstract1 | Shipboard electrical power systems (SEPS) are isolated and autonomous. Voltage unbalance can occur in a three-phase system due to the non-zero impedance of the power source and differences in phase loads. The power quality by the unbalance factor is considered to be in compliance with the standards if the total duration of its going beyond the normally permissible values (2%) is no more than 1 hour and 12 minutes per day. In addition, there should be no measurements exceeding the maximum permissible value (4%). In electric machines (e.g. induction motors), due to the appearance of additional magnetic fields rotating in the direction opposite to the direction of the rotor rotation, their service term is reduced by 10-15%. The efficiency of power (synchronous) generators is decreased. Also, voltage unbalance leads to an increase in losses in the neutral wire during power transmission. In this case, disruption of uninterrupted power supply, disruption of computers and other equipment is possible. Therefore, it is relevant to improve the systems for measuring and monitoring the quality of electricity in three-phase networks. | uk_UA |
dc.description.provenance | Submitted by Олександр Ушкаренко (oleksandr.ushkarenko@nuos.edu.ua) on 2022-06-10T19:03:28Z No. of bitstreams: 1 Ushkarenko_thesis.pdf: 394962 bytes, checksum: 56371e8020cbd87cdecec41187e19528 (MD5) | en |
dc.description.provenance | Approved for entry into archive by Катерина Білоножко (kateryna.bilonozhko@nuos.edu.ua) on 2022-06-11T15:43:46Z (GMT) No. of bitstreams: 1 Ushkarenko_thesis.pdf: 394962 bytes, checksum: 56371e8020cbd87cdecec41187e19528 (MD5) | en |
dc.description.provenance | Approved for entry into archive by Катерина Білоножко (kateryna.bilonozhko@nuos.edu.ua) on 2022-06-11T19:23:08Z (GMT) No. of bitstreams: 1 Ushkarenko_thesis.pdf: 394962 bytes, checksum: 56371e8020cbd87cdecec41187e19528 (MD5) | en |
dc.description.provenance | Made available in DSpace on 2022-06-11T19:23:28Z (GMT). No. of bitstreams: 1 Ushkarenko_thesis.pdf: 394962 bytes, checksum: 56371e8020cbd87cdecec41187e19528 (MD5) | en |
dc.identifier.uri | https://eir.nuos.edu.ua/handle/123456789/5346 | |
dc.language.iso | en | uk_UA |
dc.subject | voltage asymmetry | uk_UA |
dc.subject | marine power system | uk_UA |
dc.subject | quality of electricity | uk_UA |
dc.subject | несиметрія напруги | uk_UA |
dc.subject | суднова електроенергетична система | uk_UA |
dc.subject | якість електроенергії | uk_UA |
dc.title | Improvement of monitoring means of voltage unbalance factor in shipboard electrical power system | uk_UA |
dc.title2 | 2021 | |
dc.type | Thesis | uk_UA |
Файли
Контейнер файлів
1 - 1 з 1
Вантажиться...
- Назва:
- Ushkarenko_thesis.pdf
- Розмір:
- 385.71 KB
- Формат:
- Adobe Portable Document Format
- Опис:
- тези
Ліцензійна угода
1 - 1 з 1
Ескіз недоступний
- Назва:
- license.txt
- Розмір:
- 7.05 KB
- Формат:
- Item-specific license agreed upon to submission
- Опис: