Increasing the Operation Efficiency of Air Conditioning System for Integrated Power Plant on the Base of Its Monitoring
dc.contributor.author | Trushliakov, Eugeniy | |
dc.contributor.author | Radchenko, Andrii | |
dc.contributor.author | Forduy, Serhiy | |
dc.contributor.author | Zubarev, Anatolii | |
dc.contributor.author | Hrych, Artem | |
dc.date.accessioned | 2021-09-06T11:44:32Z | |
dc.date.available | 2021-09-06T11:44:32Z | |
dc.date.issued | 2020 | |
dc.description | Increasing the Operation Efficiency of Air Conditioning System for Integrated Power Plant on the Base of Its Monitoring / E. Trushliakov, A. Radchenko, S. Forduy, A. Zubarev, A. Hrych // Advances in intelligent systems and computing. – 2020. – Т. 1113 AISC . – P. 351–360 | uk_UA |
dc.description.abstract1 | Abstract. The efficiency of reciprocating gas engines of integrated energy systems (IES) for combined electricity, heat and refrigeration generation is strictly influenced by their cyclic air temperatures. To evaluate the effect of gas engine cyclic air deep cooling, compared with conventional its cooling, the data on dependence of fuel consumption and power output of gas engine JMS 420 GS-N.L on its inlet air temperature at varying ambient air temperatures at the entrance of the radiator for scavenge air cooling were received. The results of treatment of gas engine efficiency monitoring proved non-effective operation of conventional chilling all the ambient air, coming into the engine room, because of increased air temperature at the inlet of turbocharger (TC), caused by heat influx from surroundings in the engine room. A new method of gas engine inlet air two-stage cooling at increased ambient air temperatures and advanced cyclic air cooling system with absorption lithium-bromide chiller and refrigerant ejector chiller was proposed. With this chilled water from absorption lithiumbromide chiller is used as a coolant in the first high-temperature stage of engine inlet air cooler and boiling refrigerant of ejector chiller in the second lowtemperature stage. | uk_UA |
dc.description.provenance | Submitted by Диндеренко Катерина (kateryna.dynderenko@nuos.edu.ua) on 2021-09-06T11:42:26Z No. of bitstreams: 1 Trushliakov 18.pdf: 853227 bytes, checksum: f1b6b46f45894cfa1d2bd9e77495cf0a (MD5) | en |
dc.description.provenance | Approved for entry into archive by Диндеренко Катерина (kateryna.dynderenko@nuos.edu.ua) on 2021-09-06T11:43:10Z (GMT) No. of bitstreams: 1 Trushliakov 18.pdf: 853227 bytes, checksum: f1b6b46f45894cfa1d2bd9e77495cf0a (MD5) | en |
dc.description.provenance | Approved for entry into archive by Диндеренко Катерина (kateryna.dynderenko@nuos.edu.ua) on 2021-09-06T11:43:52Z (GMT) No. of bitstreams: 1 Trushliakov 18.pdf: 853227 bytes, checksum: f1b6b46f45894cfa1d2bd9e77495cf0a (MD5) | en |
dc.description.provenance | Made available in DSpace on 2021-09-06T11:44:32Z (GMT). No. of bitstreams: 1 Trushliakov 18.pdf: 853227 bytes, checksum: f1b6b46f45894cfa1d2bd9e77495cf0a (MD5) | en |
dc.identifier.govdoc | https://doi.org/10.1007/978-3-030-37618-5_30 | |
dc.identifier.issn | 2194-5357 | |
dc.identifier.uri | https://eir.nuos.edu.ua/handle/123456789/4322 | |
dc.language.iso | en | uk_UA |
dc.subject | Gas engine | uk_UA |
dc.subject | Integrated energy system | uk_UA |
dc.subject | Fuel consumption | uk_UA |
dc.subject | Air cooling | uk_UA |
dc.subject | Chiller | uk_UA |
dc.title | Increasing the Operation Efficiency of Air Conditioning System for Integrated Power Plant on the Base of Its Monitoring | uk_UA |
dc.title2 | 2020 | |
dc.type | Article | uk_UA |
Файли
Контейнер файлів
1 - 1 з 1
Вантажиться...
- Назва:
- Trushliakov 18.pdf
- Розмір:
- 833.23 KB
- Формат:
- Adobe Portable Document Format
- Опис:
- стаття
Ліцензійна угода
1 - 1 з 1
Ескіз недоступний
- Назва:
- license.txt
- Розмір:
- 7.05 KB
- Формат:
- Item-specific license agreed upon to submission
- Опис: